YTE Dehumidifier Fault Analysis and Repair Guide (Part 2)

2024-01-02 13:07 YTE HVAC Senior Program Manager: BJ Chen
2

FAQ-min.png


To ensure the continuous and efficient operation of your dehumidifier, YTE provides a comprehensive fault analysis and repair guide, covering everything from ventilation system faults to electrical system issues, as well as specific problems with the refrigeration system and compressor. This guide is designed to help users quickly identify and resolve common issues.

1. Troubleshooting Sequence for Dehumidifiers Not Dehumidifying:

  • Ventilation System Faults:

    • Intake and exhaust grates: Check for physical damage or aging cracks, and whether intake or exhaust is obstructed.

    • Air filter: Check for blockage or damage by dust.

    • Evaporator: Inspect if condenser fins are dusty or if the evaporator surface is frozen.

    • Fan motor: Examine if capacitors are damaged, if the fan motor is jammed, if the rotor and shaft are loose, if the shaft is bent or deformed, if bearings are damaged (including oil bearings with evaporated lubricant or ball bearings with worn balls), or if the winding is burnt out.

    • Fan blades: Check if screws are loose, if fan blades are deformed or damaged, if blades are heavily dusted affecting airflow, or if small dehumidifier blades are jammed due to heavy dust.


  • Electrical System Faults:

    • Both compressor and fan not turning: Check if the power is cut off, if the switch is on, if the socket is disconnected, if the voltage is too low, if the circuit breaker is tripped, if the fuse is burnt out, or if the compressor is in a three-minute protection mode.

    • Compressor not turning, fan is turning: Inspect if relays, capacitors, or overload protection are faulty.

    • Both compressor and fan are running: This might indicate a refrigeration system fault.


  • Refrigeration System Faults:

    • Check if the refrigerant has completely leaked out.

    • Inspect if the refrigeration system is blocked: dirt blockage, oil blockage, or welding blockage.

    • Determine if there is an excessive amount of refrigerant.

    • Assess if the compressor has no displacement.


  • Compressor Faults:

    • Poor compression, high and low-pressure chamber gas leakage.

    • Damaged operating parts, compressor seizing.


2. Troubleshooting Sequence for Increased Noise in Dehumidifiers:

  1. Uneven ground causing the dehumidifier to be unstable.

  2. Loose parts on the dehumidifier.

  3. Foreign objects inside the dehumidifier.

  4. Damaged or deformed fan blades disrupting dynamic balance.

  5. Starter faults.

  6. Collisions between pipes (copper pipes).

  7. Lack of oil in the fan.

  8. Fan bearing faults (including oil bearings with evaporated lubricant or ball bearings with worn balls).

  9. Excessive noise from the compressor.

  10. Overfilling of refrigerant or lubricant causing liquid strike.

3. Troubleshooting Sequence for Dehumidifiers Leaking Water onto the Floor:

  1. The dehumidifier is not placed evenly, causing the water collection tray to tilt excessively and water to spill out.

  2. The drainage hole or pipe of the water collection tray is blocked.

  3. The water collection tray is damaged and leaking.

  4. The water pipe connection is leaking or the water pipe is aged and cracked.

Through this guide, YTE aims to help users better understand and maintain their dehumidifiers, ensuring the continuous and efficient operation of the equipment. If you encounter any problems, please contact YTE's professional repair team.

Keywords:

YTE Dehumidifier, Fault Analysis, Repair Guide, Ventilation System Fault, Electrical System Fault, Refrigeration System Fault, Compressor Fault, Noise Issues, Water Flow Fault, Repair Strategies, Troubleshooting, Dehumidification Efficiency, Maintenance Instructions, Professional Repair Team.


If your on-site conditions are complex, it is essential to undergo rigorous calculations to achieve optimal temperature and humidity. You can also communicate with professional engineers from the YTE Temperature and Humidity Management Division through the YTE China service hotline or email.


2023125


YTE Group: Leading Comprehensive and Innovative Solutions in Special Environment Control

YTE Group is a leading enterprise in the field of special environment control. The company's headquarters is located in Ningbo, Zhejiang, a famous modern manufacturing center in China, situated at the core of the Yangtze River Delta region.

As a national high-tech enterprise centered on technological innovation, YTE Group is dedicated to integrating research and development, manufacturing, marketing, engineering installation, and services to provide comprehensive and professional environmental control vertical solutions for global customers.

Our goal is to create efficient and reliable environmental control systems through continuous technological innovation, ensuring our clients' outstanding performance in various special environments.


[End]


name:
Message:
Verification code:
submit
Comment